Comparison · deep groove ball bearings · 25 mm bore

6205 vs 6305: same shaft seat, two different answers

These two designations are the same bore in two sections of the deep groove dimension plan: the light 6205 (25 mm × 52 mm × 15 mm mm) and the medium 6305 (25 mm × 62 mm × 17 mm mm). Everything else on this page follows from that one decision — how much ring section your housing can give up, and how much load the position has to carry. Both designations are published with model-bound catalog figures; the table below adds nothing to them, and a cell we have not published renders as a gap rather than a guess.

Last updated: 2026-11

Side-by-side catalog specifications

Attribute 6205
Manufacturer: Koyo / JTEKT
Source configuration: open
6305
Manufacturer: Koyo / JTEKT
Source configuration: open
Bore diameter (d) 25 mm
standard-model · jtekt.co.jp · Manufacturer-published specification
25 mm
standard-model · jtekt.co.jp · Manufacturer-published specification
Outside diameter (D) 52 mm
standard-model · jtekt.co.jp · Manufacturer-published specification
62 mm
standard-model · jtekt.co.jp · Manufacturer-published specification
Width (B) 15 mm
standard-model · jtekt.co.jp · Manufacturer-published specification
17 mm
standard-model · jtekt.co.jp · Manufacturer-published specification
Basic dynamic load rating (Cr) 17.5 kN
reference-manufacturer · jtekt.co.jp · Manufacturer-published specification · Basic dynamic load rating is a catalog reference used in bearing-life calculations; confirm equivalent load, speed, reliability and required service life for the application.
25.7 kN
reference-manufacturer · jtekt.co.jp · Manufacturer-published specification · Basic dynamic load rating is a catalog reference used in bearing-life calculations; confirm equivalent load, speed, reliability and required service life for the application.
Basic static load rating (C0r) 7.85 kN
reference-manufacturer · jtekt.co.jp · Manufacturer-published specification · Basic static load rating is a catalog reference; verify equivalent static load and the required static safety factor for the application.
11.3 kN
reference-manufacturer · jtekt.co.jp · Manufacturer-published specification · Basic static load rating is a catalog reference; verify equivalent static load and the required static safety factor for the application.
Fatigue load limit (Cu) —
No published value in the evidence record
—
No published value in the evidence record
Limiting speed, grease 13000 min-1
reference-manufacturer · jtekt.co.jp · Manufacturer-published specification · Catalog limiting speed for grease lubrication, not an application operating recommendation. Confirm lubricant, temperature, load, sealing and duty conditions before selection.
11000 min-1
reference-manufacturer · jtekt.co.jp · Manufacturer-published specification · Catalog limiting speed for grease lubrication, not an application operating recommendation. Confirm lubricant, temperature, load, sealing and duty conditions before selection.
Limiting speed, oil 15000 min-1
reference-manufacturer · jtekt.co.jp · Manufacturer-published specification · Catalog limiting speed for oil lubrication, not an application operating recommendation. Confirm lubricant, temperature, load, sealing and duty conditions before selection.
13000 min-1
reference-manufacturer · jtekt.co.jp · Manufacturer-published specification · Catalog limiting speed for oil lubrication, not an application operating recommendation. Confirm lubricant, temperature, load, sealing and duty conditions before selection.
Shaft abutment (da min.) 30 mm
standard-model · jtekt.co.jp · Manufacturer-published specification
31.5 mm
standard-model · jtekt.co.jp · Manufacturer-published specification
Housing abutment (Da max.) 47 mm
standard-model · jtekt.co.jp · Manufacturer-published specification
55.5 mm
standard-model · jtekt.co.jp · Manufacturer-published specification
Reference mass 0.128 kg
reference-manufacturer · jtekt.co.jp · Manufacturer-published specification
0.232 kg
reference-manufacturer · jtekt.co.jp · Manufacturer-published specification

Both columns are the same model-bound catalog figures as on the linked specification pages — this page derives nothing and rounds nothing. A dash means that field is not published for that designation yet; ask for it in the inquiry and we confirm at quotation.

Where the 6205 is the right answer

The 6205's narrower ring section and smaller outside diameter buy space and mass, and — as the table shows — a higher limiting speed than the 6305. It is the standard choice when the load is moderate for the shaft size, the housing is compact (note the smaller housing abutment diameter), and speed matters: electric tools, small gearboxes, fan positions, general machinery at small-to-medium duty. Its lower ratings are not a weakness if the application's load stays inside them — rating life is calculated from the load ratio, not from the bigger number.

Where the 6305 is the right answer

The 6305 spends its extra section on capacity: a higher dynamic and static rating in the same 25 mm bore, at the cost of a larger housing requirement, more mass and lower limiting speeds. It is the standard answer for heavier radial duty on the same shaft — conveyor head pulleys, larger gear stages, agitators, fans and compressors where the load spectrum or the shock level rules out the light series. If your housing already fits a 62xx outside diameter, moving to 63xx means re-machining the seat — which is exactly why this decision belongs at design time, not at replacement time.

What this comparison does not say

Same bore is not interchange: the two bearings are not substitutes for each other, they are different designs that happen to fit the same shaft seat. Clearances, cage designs and available executions (open, ZZ, 2RS) are confirmed per designation — check each model page and, if you are replacing an existing fitting, our guide to finding a replacement and the load-speed-space selection overview. The trade between series at a fixed bore is one axis; load-and-life selection and speed and temperature limits decide the rest.