Comparison · 20 mm bore · two families, one boundary
7204B vs 6204: identical envelope, different families
This is the comparison people ask for the moment they see the tables: the angular contact 7204B and the deep groove 6204 occupy exactly the same 20 × 47 × 14 mm envelope. The resemblance ends at the envelope. The families distribute load differently, their catalog speeds and ratings differ (both sets are shown below, unchanged from their model pages), and they are not drop-in substitutes for each other — the last section on this page says why.
Last updated: 2026-11
Side-by-side catalog specifications
| Attribute | 7204B (angular contact) Manufacturer: Koyo / JTEKT Source configuration: single-row, pressed cage | 6204 (deep groove) Manufacturer: Koyo / JTEKT Source configuration: open |
|---|---|---|
| Bore diameter (d) | 20 mm standard-model · koyo.jtekt.co.jp · Manufacturer-published specification | 20 mm standard-model · koyo.jtekt.co.jp · Manufacturer-published specification |
| Outside diameter (D) | 47 mm standard-model · koyo.jtekt.co.jp · Manufacturer-published specification | 47 mm standard-model · koyo.jtekt.co.jp · Manufacturer-published specification |
| Width (B) | 14 mm standard-model · koyo.jtekt.co.jp · Manufacturer-published specification | 14 mm standard-model · koyo.jtekt.co.jp · Manufacturer-published specification |
| Basic dynamic load rating (Cr) | 17.6 kN reference-manufacturer · koyo.jtekt.co.jp · Manufacturer-published specification · Basic dynamic load rating is a catalog reference used in bearing-life calculations; confirm equivalent load, speed, reliability and required service life for the application. | 16 kN reference-manufacturer · koyo.jtekt.co.jp · Manufacturer-published specification · Basic dynamic load rating is a catalog reference used in bearing-life calculations; confirm equivalent load, speed, reliability and required service life for the application. |
| Basic static load rating (C0r) | 8.4 kN reference-manufacturer · koyo.jtekt.co.jp · Manufacturer-published specification · Basic static load rating is a catalog reference; verify equivalent static load and the required static safety factor for the application. | 6.65 kN reference-manufacturer · koyo.jtekt.co.jp · Manufacturer-published specification · Basic static load rating is a catalog reference; verify equivalent static load and the required static safety factor for the application. |
| Fatigue load limit (Cu) | 0.55 kN reference-manufacturer · koyo.jtekt.co.jp · Manufacturer-published specification · Fatigue load limit is a catalog reference, not a standalone allowable-load or service-life guarantee; verify application duty and lubrication conditions. | 0.51 kN reference-manufacturer · koyo.jtekt.co.jp · Manufacturer-published specification · Fatigue load limit is a catalog reference, not a standalone allowable-load or service-life guarantee; verify application duty and lubrication conditions. |
| Limiting speed, grease | 10000 min-1 reference-manufacturer · koyo.jtekt.co.jp · Manufacturer-published specification · Catalog limiting speed for grease lubrication, not an application operating recommendation. Confirm lubricant, temperature, load, sealing and duty conditions before selection. | 15000 min-1 reference-manufacturer · koyo.jtekt.co.jp · Manufacturer-published specification · Catalog limiting speed for grease lubrication, not an application operating recommendation. Confirm lubricant, temperature, load, sealing and duty conditions before selection. |
| Limiting speed, oil | 13000 min-1 reference-manufacturer · koyo.jtekt.co.jp · Manufacturer-published specification · Catalog limiting speed for oil lubrication, not an application operating recommendation. Confirm lubricant, temperature, load, sealing and duty conditions before selection. | 17000 min-1 reference-manufacturer · koyo.jtekt.co.jp · Manufacturer-published specification · Catalog limiting speed for oil lubrication, not an application operating recommendation. Confirm lubricant, temperature, load, sealing and duty conditions before selection. |
| Shaft abutment (da min.) | 25.5 mm standard-model · jtekt.co.jp · Manufacturer-published specification | 25 mm standard-model · koyo.jtekt.co.jp · Manufacturer-published specification |
| Housing abutment (Da max.) | 41.5 mm standard-model · jtekt.co.jp · Manufacturer-published specification | 42 mm standard-model · koyo.jtekt.co.jp · Manufacturer-published specification |
| Reference mass | 0.112 kg reference-manufacturer · jtekt.co.jp · Manufacturer-published specification | 0.106 kg reference-manufacturer · koyo.jtekt.co.jp · Manufacturer-published specification |
Every cell is the model-bound catalog figure from the linked specification page — this page adds and rounds nothing. A dash means the field is not published for that designation.
What the families do differently
A deep groove 6204 carries radial load as its primary duty and accepts a limited axial component in either direction — the general-purpose answer when loads are mostly radial and the direction can reverse. An angular contact 7204B carries its contact angle like a ramp: substantial axial capacity in one direction only, and it is normally mounted so that a companion bearing (or its pair) takes the reverse direction. That is the structural difference behind every cell above.
Note what the identical envelope hides: even with the same boundary dimensions, internal clearance, contact angle, cage and pairing provisions are family-specific. A 7204B cannot simply be dropped into a housing machined for a 6204 and expected to behave like one — its one-directional axial design needs the arrangement to match, and its published speed ratings are lower than the deep groove's.
Which one, then?
If the position sees mostly radial load with incidental, reversing axial components, the deep groove 6204 is the simpler and usually correct answer — and the higher published limiting speeds come with it. If the position carries a sustained axial load in a known direction (spindle, pump thrust, helical gear reactions), the angular contact 7204B exists for exactly that case, typically as one bearing of a pair. When you are replacing an existing bearing, identify what is actually installed before comparing families — our replacement guide walks that check. The family trade-off in depth is in deep groove vs angular contact and contact angle and axial capacity; paired mounting is covered in pairing and preload.