03 — Selection & applications
(a) Housing series and bore attachment
The SNT catalog organizes its housings by the bearing attachment they take:
two-bolt and four-bolt housings for tapered-bore bearings in the 500/600
series, two- and four-bolt housings for cylindrical-bore bearings in the
200/300 series, four-bolt SNTD housings for the larger 3000/3100 series,
and SNTN housings for the 3000 light series. The nomenclature section
covers 200-300, 500-600, 3000 and 3100 series — in other words, the
mounting geometry and the bearing's shaft attachment (tapered versus
cylindrical) are decided together, not independently. A four-bolt base is
the stiffer choice where loads are heavy or reversing; the catalog's
dedicated "housing strength" chapter exists because the housing, not the
bearing inside it, is the structure carrying those loads to the frame.
(b) Seals: four options, four environments
The catalog names four seal options — double-lip, labyrinth, V-ring and
taconite — a spread that maps to escalating contamination: double-lip for
ordinary grease-lubricated duty, labyrinth where particulate persists,
V-ring as an exile-to-the-shaft solution, taconite where abrasive dust is
severe enough to need a multi-stage barrier. The catalog's stated purpose
for the whole line — "keep lubrication in and contamination out" — is the
selection criterion: match the seal to the worst condition the unit sees,
not the average one.
(c) Lubrication as a designed path
The SNT line's lubrication feature is a center-mounted grease fitting
matched to the bearing lube ring and holes, with other fitting locations
optional. That matters because relubrication is the maintenance act that
keeps housed units alive; a housing whose grease path cannot actually feed
the bearing's own features turns regreasing into a no-op. When comparing
housings, ask where the grease goes — the catalog documents the answer for
its own line.
(d) Housing styles: what the evidence actually covers
A mounted unit, as the category is generally defined, is a ball or roller
bearing inserted into a housing that bolts to the machine while the inner
ring mounts on the shaft — with a set screw in the common insert execution
(emersonbearing.com selection guide, fetched 2026-11-17). Standard housing
shapes named there include flange, pillow and hangar styles. This hub's
collected manufacturer record documents the pillow-block family in its
split plummer block form (the Timken SNT line). Take-up and cartridge
executions have no collected record in this evidence set, so this page
states no selection rule for them (evidence record f01; gap
gap:03:no-takeup-cartridge-record).
(e) Fixed or float: load direction is a published table axis
The SNT catalog treats load direction as a first-class selection input:
its housing safe-load table is organized by load direction (0°, 55°, 90°,
120°, 150°, 180° and axial, section 02 above), so which direction the load
comes from changes the rating before anything else does. Whether the unit
locates the shaft axially is a separate, explicit choice — the catalog's
locating rings "provide flexibility to fix or float the bearing", and the
same housing can be applied "in fixed or float positions, and open or
closed with end covers" depending on the accessories chosen
(cad.timken.com, Timken® SNT Split Plummer Blocks mini catalog, pp. 4, 7;
fetched 2026-11-16; evidence records f02–f04). A typical arrangement:
one fixed unit takes the axial thrust, the opposing float unit absorbs
shaft thermal growth — a boundary decided by the load path, not the
bolt pattern.
(f) Seals set the environment and speed boundary — with numbers
The catalog publishes a seal-selection table (p. 7) that turns "match the
seal to the environment" into checkable limits. Temperature windows:
−40 to 100 °C for double-lip (TSNG), V-ring (VR) and taconite (TA);
−40 to 120 °C for labyrinth (LO). Maximum linear speed: 8 m/s double-lip,
7 m/s V-ring, 7 m/s taconite, and for the labyrinth "same as bearing" —
the seal stops being the speed limiter only in that one execution.
Misalignment allowance falls with shaft diameter and seal type: at
shaft dia ≤ 100 mm the table allows 1° (double-lip), 1.5° (V-ring),
0.3° (labyrinth), 0.3° (taconite); above 100 mm it drops to 0.5°, 1°,
0.3°, 0.3° respectively. Particle and water resistance split the field:
double-lip and labyrinth rate Excellent against dust/fine particles,
labyrinth and taconite Excellent against coarse particles, and the
V-ring — best on relubrication and friction — rates only Fair against
coarse particles. The buyer takeaway the table supports: a housing is
selected against its worst operating condition, and the catalog
gives the numbers to do that per seal, not per brochure claim (evidence
records f05–f09).
(g) Fits, fretting and replacement guidance
Fit rules have a direction. SKF's rolling-bearings handbook states the
load-based rule: the ring subjected to the rotating load should have an
interference fit; under stationary load the ring "typically has a loose
fit"; when the load direction is indeterminate with heavy loads, an
interference fit on both rings is recommended. The cost of getting a fit
wrong runs both ways: too loose — fretting, smearing and wear, with ring
fracture a risk under heavy loads; too tight — the internal clearance
loss raises operating temperature, accelerates lubricant deterioration
and can fail the bearing prematurely
(cdn.skfmediahub.skf.com, SKF "Rolling bearings and seals in electric
motors and generators", pp. 67–69, 121; fetched 2026-11-17; evidence
records f10–f12). The same handbook identifies the mechanism buyers see
as rust in the housing bore: fretting corrosion starts as micro-movements
between the bearing outside diameter and the housing (or bore and shaft),
driven by the cyclic passage of rolling elements, aggravated by
inadequate fit, shaft bending or rough contact surfaces; the iron oxide
it forms occupies more volume than steel and can grow into the raceway
and precipitate premature fatigue (evidence record f13).
Replacement practice follows from those mechanisms. On the bearing side,
the SNT procedure for a tapered-bore spherical roller bearing is to
measure radial internal clearance before installation, then tighten the
locknut until the clearance reaches the target — the catalog's worked
example takes a 22328K C3 (140 mm bore) from a measured 0.178 mm down to
0.102 mm after mounting, and warns that the table's directly-read
suggested value (0.056 mm in that example) is a minimum the calculated
figure must not fall below; clearance is re-checked at the unloaded
roller (cad.timken.com SNT mini catalog, p. 11; fetched 2026-11-16;
evidence record f14). On the housing side, the SNT split cap exists for
exactly this moment — pry-tool slots allow cap removal for "speedy
bearing inspection and replacement" — and where a fretted or deformed
seat has seized the outer ring, SKF notes that tapped holes in the
housing make dismounting possible without destroying it (evidence
records f15–f16). Field guidance from a maintenance source adds the
acceptance check: radial internal clearance measured with a dial
indicator before and after mounting — a drop greater than roughly 30%
signals an over-constraining fit, and a loose outer-ring seat (the wrong
housing tolerance class) lets the outer ring rotate under load, producing
fretting corrosion and raceway spalling
(flowmachinery.com troubleshooting guide, published 2026-02-16, fetched
2026-11-17; evidence records f17–f18).
(h) Failure modes a housed unit actually dies of
Three failure families dominate the collected sources, and each has a
visible signature before it becomes a teardown. Seizure
follows lubricant breakdown: grease cooked by sustained high temperature
loses viscosity, contact turns metal-to-metal, and the bearing seizes
(machinerylubrication.com, fetched 2026-11-17; evidence record f19) —
which is why the seal table's temperature windows in (f) are selection
boundaries, not footnotes. Fretting corrosion is the fit
failure of (g): micro-movement at the seat, oxide growth, raceway
spalling, ring cracking in advanced cases. Seal failure
shows as grease where it should not be: over-greasing churns and heats
the grease until seals extrude, and a blocked housing vent can build
enough internal pressure to force grease past the seal lip and starve the
load zone — the field source's inspection items are seal-lip contact and
vent integrity, checked on a two-week visual cycle with no visible
cracks, rust streaks or grease weepage beyond the seal lip
(flowmachinery.com, fetched 2026-11-17; evidence records f20–f21).
(i) Where this evidence set is thin
Per-part-number dimension tables for a mounted line this site publishes,
and the lighter insert-unit executions' full dimension sets, are the thin
edges of this hub. Take-up and cartridge unit selection boundaries, and
flange-style load ratings, likewise have no collected record here yet.
Absence of a part number from this page means no collected record exists
for it here, not that it is unavailable; supply is answered at quotation.
Evidence records: every claim in this section is machine-checkable against
this site's mounted-bearing-units evidence ledger (records f01–f21, sources
cad.timken.com fetched 2026-11-16; emersonbearing.com, cdn.skfmediahub.skf.com,
machinerylubrication.com, flowmachinery.com fetched 2026-11-17; copies
retained in this site's research corpus with per-source checksums).