03 — Selection & applications
(a) One shaft bore, several housing diameters
These are bores where this evidence set publishes more than one series. Each
table is generated from the published records — nothing is interpolated between
them:
Equal bore 20 mm — published values, series comparison | Designation | Series | D (housing) | Height | Cr kN | C0r kN |
| 51104 | 511 | 35 | 10 | 17.8 | 24.7 |
| 51204 | 512 | 40 | 14 | 27.9 | 37.7 |
Equal bore 25 mm — published values, series comparison | Designation | Series | D (housing) | Height | Cr kN | C0r kN |
| 51105 | 511 | 42 | 11 | 24.4 | 37.2 |
| 51205 | 512 | 47 | 15 | 34.6 | 50.4 |
| 51305 | 513 | 52 | 18 | 44.7 | 61.4 |
| 51405 | 514 | 60 | 24 | 69.5 | 89.4 |
Equal bore 50 mm — published values, series comparison | Designation | Series | D (housing) | Height | Cr kN | C0r kN |
| 51110 | 511 | 70 | 14 | 35.9 | 75.4 |
| 51210 | 512 | 78 | 22 | 60.6 | 111 |
| 51310 | 513 | 95 | 31 | 121 | 202 |
| 51410 | 514 | 110 | 43 | 185 | 283 |
The pattern the evidence supports: within one series the housing washer grows
with the bore and the rating with it; across series at one bore, the heavier
series trades housing diameter and height for rating — at the 20 mm bore from
a 35 mm washer at 10 mm height up to a 40 mm washer at 14 mm, with Cr rising
from 17.8 to 27.9 kN. The pocket, not the shaft, is what the series digit
spends.
(b) The height is usually the binding constraint
In vertical assemblies the axial space is fixed by the housing design long
before the rating becomes binding: a 511-series washer at 10-11 mm height fits
assemblies the 512-series at 14-15 mm cannot enter, and the 513/514 series more
again. The evidence shows the trade consistently — roughly half again the
published rating for four or five millimetres of height and five millimetres of
housing diameter. Where height is binding, the honest alternative is not a
heavier washer squeezed in, but checking whether the calculated axial life at
the slimmer rating still passes.
(c) Where this evidence set is thin — and what that means
Bore gaps inside each series are visible in the coverage table. Absence of a
designation from this page means no evidence record exists for it here, not
that it is unavailable. Paired-washer arrangements and the separate radial
bearing every thrust-ball assembly needs are outside what a washer record
describes; the pairing rule and its verification are covered in the selection
guide linked at the foot of this page.
(d) Can one washer take a reversing load or a tilted seat?
No on both counts, and the manufacturer guidance is blunt about it. The
single-direction construction of the 511–514 series carries axial force in one
direction only — a reversing axial load unloads the loaded washer on every
reverse, and an unloaded flat-washer set skids its balls instead of rolling
them; reversing duty needs a paired arrangement where each direction has its
own loaded washer and the relieved one is held under a minimum load (springs
are the usual means). Alignment is the second hard limit: KINEX states for this
construction that any misalignment between shaft and housing washers raises the
contact stress between rolling elements and raceways, and the execution is not
suitable for carrying load under such misalignment — there is no tolerance
budget to spend here. Spherical-seatback executions exist precisely for
tilted housings; they are a different family (see the spherical-roller thrust
hub). Decision rule: if your axial load reverses or your housing seat cannot
be machined and held square, this family is the wrong execution — fix the
duty or change the family, do not derate the washer.
(e) How fast can a thrust ball washer run — and what does the speed rating assume?
Faster than its reputation suggests, but only under conditions the catalogue
states explicitly. NSK's family overview describes this construction as
"designed to take axial (thrust) loads at high speeds" while carrying no radial
load (fetched 2026-11-15) — the speed ceiling is not the washers, it is the
sliding contact of balls on flat raceways. The published figure is always
per lubrication: the Koyo specification page for the 51100 designation
(fetched 2026-11-15) states a limiting speed of 6500 min⁻¹ under grease
lubrication and 10000 min⁻¹ under oil, for the same washer. Assume the grease
figure unless your lubrication plan genuinely delivers oil; the same page
publishes the fatigue load limit Cu (0.63 kN for 51100), which governs
static-dominated duty rather than the dynamic rating.
Two construction choices in the family also sit behind the number. First,
minimum axial load: at light axial duty the balls skid regardless of the
catalogue figure, so the usable speed collapses toward zero — section (d)
covers the preload remedy. Second, seat type: NSK classifies the family into
"flat seat" and "aligning seat" types by housing-washer shape and notes that
spherical and aligning seat washers "help to provide tolerance for mounting
errors" (fetched 2026-11-15). That tolerance is for initial mounting error at
assembly — it does not overturn the no-running-misalignment limit in section
(d); a seat that starts aligned and tilts under load still violates it.
Decision rule: read the limiting speed only against the lubrication you will
actually run, treat it as void below the datasheet minimum load, and pick the
seat type for your assembly accuracy — not for extra speed.